Menu
thumbSakret

PGP / Levelling thick layer plaster

  • For filling of surface cavities
  • For repairing of crumbled areas
  • For surfaces with a high concentration of salts
  • Frost and moisture resistant
  • Cement based
  • Layer thickness 10 - 40mm
  • For vertical surfaces
  • For external and internal works

Processing 

Surface preparation

  • If there are coatings on the surface that have a negative effect on adhesion and surface quality, they must be removed with a high-pressure washer or sandblasting
  • Before applying SAKRET VSM, fill old seams and cracks with SAKRET SP-G
  • Before applying SAKRET PGP, the surface must be treated with the adhesion material SAKRET VSM
  • If necessary, tests should be carried out on a small surface area
  • Quality ventilation must be ensured when working indoors!

Usage

  • It is used for surface repair and preparation before the application of recovery plaster SP-G
  • Layer thickness >40 mm using multi-layer application method
  • Mechanically process freshly applied material as little as possible, otherwise the content of air pores in the material may decrease
  • For mixing of PGP use tools and equipment designed for the preparation of this type of material
  • Protect the newly applied material from strong wind, direct sunlight, rain and freezing
  • The material that has started to bind should not be diluted with water, but mixed again
  • Hardened mass can only be cleaned mechanically

Instructions

  • Protect the packaging from weather conditions, store on wooden pallets, in a cool and dry place, cover torn packaging immediately
  • Contains cement, reacts alkaline
  • Protect skin and eyes, follow technical instructions. If the mortar gets into the eyes, rinse with a large amount of water, if necessary, consult a doctor

Packing

  • 25 kg / paper bags / 42 bags on a pallet

Tehnical data

Compliant with the standardConsumptionMaximum grain sizeWater penetration depthAchieving full hardnessFire safety classStorage timeStrength class (according to LVS EN 998-1)Minimum layer thickness
WTA 2-9-04/D11 - 12 kg/m²/ (if layer thickness is 10 mm)≤ 1 mm≤ 5 mmAfter 28 daysEuroclass A1 (non-flammable)12 monthsCS II10 mm
Back to Top